aboutsummaryrefslogtreecommitdiff
diff options
context:
space:
mode:
authorGravatar Hanspeter Portner <dev@open-music-kontrollers.ch>2014-11-16 14:13:00 +0100
committerGravatar Hanspeter Portner <dev@open-music-kontrollers.ch>2014-11-16 14:13:00 +0100
commit4c82f3fd0ef1146e0e3d119d854fe86c1be1e892 (patch)
tree164ad58cd9db9362b9bc02884d82122c77979487
parent398dbf4f86278cd9296fec989f0fac8c0ec2b0c3 (diff)
downloadchimaera_sensor_unit-4c82f3fd0ef1146e0e3d119d854fe86c1be1e892.zip
chimaera_sensor_unit-4c82f3fd0ef1146e0e3d119d854fe86c1be1e892.tar.gz
chimaera_sensor_unit-4c82f3fd0ef1146e0e3d119d854fe86c1be1e892.tar.bz2
chimaera_sensor_unit-4c82f3fd0ef1146e0e3d119d854fe86c1be1e892.tar.xz
update Digi-Key part number for A1304
-rw-r--r--chimaera_sensor_unit-cache.lib2
-rw-r--r--chimaera_sensor_unit.pro2
-rw-r--r--chimaera_sensor_unit.sch34
3 files changed, 19 insertions, 19 deletions
diff --git a/chimaera_sensor_unit-cache.lib b/chimaera_sensor_unit-cache.lib
index 57193e6..ce735cb 100644
--- a/chimaera_sensor_unit-cache.lib
+++ b/chimaera_sensor_unit-cache.lib
@@ -1,4 +1,4 @@
-EESchema-LIBRARY Version 2.3 Date: Don 12 Jun 2014 09:15:08 CEST
+EESchema-LIBRARY Version 2.3 Date: Son 16 Nov 2014 14:12:18 CET
#encoding utf-8
#
# A1326
diff --git a/chimaera_sensor_unit.pro b/chimaera_sensor_unit.pro
index 6b9d48a..e13eae7 100644
--- a/chimaera_sensor_unit.pro
+++ b/chimaera_sensor_unit.pro
@@ -1,4 +1,4 @@
-update=Don 12 Jun 2014 09:59:06 CEST
+update=Son 16 Nov 2014 14:12:25 CET
last_client=kicad
[cvpcb]
version=1
diff --git a/chimaera_sensor_unit.sch b/chimaera_sensor_unit.sch
index 94f5f21..c16a8c9 100644
--- a/chimaera_sensor_unit.sch
+++ b/chimaera_sensor_unit.sch
@@ -41,7 +41,7 @@ $Descr A4 11693 8268
encoding utf-8
Sheet 1 1
Title "Chimaera Sensor Unit (SU-16)"
-Date "12 jun 2014"
+Date "16 nov 2014"
Rev "8-3v3"
Comp "Open Music Kontrollers (www.open-music-kontrollers.ch)"
Comment1 "Licensed under CERN OHL v.1.2"
@@ -738,7 +738,7 @@ F 0 "S15" H 9150 6550 50 0000 C CNN
F 1 "A13xx" H 9150 6750 50 0000 C CNN
F 2 "MODULE" H 9150 6650 50 0001 C CNN
F 3 "DOCUMENTATION" H 9150 6650 50 0001 C CNN
-F 4 "620-1019-1-ND" H 9150 6650 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 9150 6650 60 0001 C CNN "Digi-Key"
1 9150 6650
1 0 0 -1
$EndComp
@@ -750,7 +750,7 @@ F 0 "S11" H 2000 6550 50 0000 C CNN
F 1 "A13xx" H 2000 6750 50 0000 C CNN
F 2 "MODULE" H 2000 6650 50 0001 C CNN
F 3 "DOCUMENTATION" H 2000 6650 50 0001 C CNN
-F 4 "620-1019-1-ND" H 2000 6650 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 2000 6650 60 0001 C CNN "Digi-Key"
1 2000 6650
-1 0 0 -1
$EndComp
@@ -762,7 +762,7 @@ F 0 "S10" H 2000 5750 50 0000 C CNN
F 1 "A13xx" H 2000 5950 50 0000 C CNN
F 2 "MODULE" H 2000 5850 50 0001 C CNN
F 3 "DOCUMENTATION" H 2000 5850 50 0001 C CNN
-F 4 "620-1019-1-ND" H 2000 5850 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 2000 5850 60 0001 C CNN "Digi-Key"
1 2000 5850
-1 0 0 -1
$EndComp
@@ -774,7 +774,7 @@ F 0 "S9" H 2000 4900 50 0000 C CNN
F 1 "A13xx" H 2000 5100 50 0000 C CNN
F 2 "MODULE" H 2000 5000 50 0001 C CNN
F 3 "DOCUMENTATION" H 2000 5000 50 0001 C CNN
-F 4 "620-1019-1-ND" H 2000 5000 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 2000 5000 60 0001 C CNN "Digi-Key"
1 2000 5000
-1 0 0 -1
$EndComp
@@ -786,7 +786,7 @@ F 0 "S8" H 2000 4050 50 0000 C CNN
F 1 "A13xx" H 2000 4250 50 0000 C CNN
F 2 "MODULE" H 2000 4150 50 0001 C CNN
F 3 "DOCUMENTATION" H 2000 4150 50 0001 C CNN
-F 4 "620-1019-1-ND" H 2000 4150 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 2000 4150 60 0001 C CNN "Digi-Key"
1 2000 4150
-1 0 0 -1
$EndComp
@@ -798,7 +798,7 @@ F 0 "S7" H 2000 3250 50 0000 C CNN
F 1 "A13xx" H 2000 3450 50 0000 C CNN
F 2 "MODULE" H 2000 3350 50 0001 C CNN
F 3 "DOCUMENTATION" H 2000 3350 50 0001 C CNN
-F 4 "620-1019-1-ND" H 2000 3350 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 2000 3350 60 0001 C CNN "Digi-Key"
1 2000 3350
-1 0 0 -1
$EndComp
@@ -810,7 +810,7 @@ F 0 "S6" H 2000 2450 50 0000 C CNN
F 1 "A13xx" H 2000 2650 50 0000 C CNN
F 2 "MODULE" H 2000 2550 50 0001 C CNN
F 3 "DOCUMENTATION" H 2000 2550 50 0001 C CNN
-F 4 "620-1019-1-ND" H 2000 2550 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 2000 2550 60 0001 C CNN "Digi-Key"
1 2000 2550
-1 0 0 -1
$EndComp
@@ -822,7 +822,7 @@ F 0 "S5" H 2000 1650 50 0000 C CNN
F 1 "A13xx" H 2000 1850 50 0000 C CNN
F 2 "MODULE" H 2000 1750 50 0001 C CNN
F 3 "DOCUMENTATION" H 2000 1750 50 0001 C CNN
-F 4 "620-1019-1-ND" H 2000 1750 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 2000 1750 60 0001 C CNN "Digi-Key"
1 2000 1750
-1 0 0 -1
$EndComp
@@ -834,7 +834,7 @@ F 0 "S4" H 2000 900 50 0000 C CNN
F 1 "A13xx" H 2000 1100 50 0000 C CNN
F 2 "MODULE" H 2000 1000 50 0001 C CNN
F 3 "DOCUMENTATION" H 2000 1000 50 0001 C CNN
-F 4 "620-1019-1-ND" H 2000 1000 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 2000 1000 60 0001 C CNN "Digi-Key"
1 2000 1000
-1 0 0 -1
$EndComp
@@ -862,7 +862,7 @@ F 0 "S0" H 9150 900 50 0000 C CNN
F 1 "A13xx" H 9150 1100 50 0000 C CNN
F 2 "MODULE" H 9150 1000 50 0001 C CNN
F 3 "DOCUMENTATION" H 9150 1000 50 0001 C CNN
-F 4 "620-1019-1-ND" H 9150 1000 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 9150 1000 60 0001 C CNN "Digi-Key"
1 9150 1000
1 0 0 -1
$EndComp
@@ -874,7 +874,7 @@ F 0 "S1" H 9150 1650 50 0000 C CNN
F 1 "A13xx" H 9150 1850 50 0000 C CNN
F 2 "MODULE" H 9150 1750 50 0001 C CNN
F 3 "DOCUMENTATION" H 9150 1750 50 0001 C CNN
-F 4 "620-1019-1-ND" H 9150 1750 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 9150 1750 60 0001 C CNN "Digi-Key"
1 9150 1750
1 0 0 -1
$EndComp
@@ -886,7 +886,7 @@ F 0 "S2" H 9150 2450 50 0000 C CNN
F 1 "A13xx" H 9150 2650 50 0000 C CNN
F 2 "MODULE" H 9150 2550 50 0001 C CNN
F 3 "DOCUMENTATION" H 9150 2550 50 0001 C CNN
-F 4 "620-1019-1-ND" H 9150 2550 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 9150 2550 60 0001 C CNN "Digi-Key"
1 9150 2550
1 0 0 -1
$EndComp
@@ -898,7 +898,7 @@ F 0 "S3" H 9150 3250 50 0000 C CNN
F 1 "A13xx" H 9150 3450 50 0000 C CNN
F 2 "MODULE" H 9150 3350 50 0001 C CNN
F 3 "DOCUMENTATION" H 9150 3350 50 0001 C CNN
-F 4 "620-1019-1-ND" H 9150 3350 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 9150 3350 60 0001 C CNN "Digi-Key"
1 9150 3350
1 0 0 -1
$EndComp
@@ -910,7 +910,7 @@ F 0 "S12" H 9150 4050 50 0000 C CNN
F 1 "A13xx" H 9150 4250 50 0000 C CNN
F 2 "MODULE" H 9150 4150 50 0001 C CNN
F 3 "DOCUMENTATION" H 9150 4150 50 0001 C CNN
-F 4 "620-1019-1-ND" H 9150 4150 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 9150 4150 60 0001 C CNN "Digi-Key"
1 9150 4150
1 0 0 -1
$EndComp
@@ -922,7 +922,7 @@ F 0 "S13" H 9150 4900 50 0000 C CNN
F 1 "A13xx" H 9150 5100 50 0000 C CNN
F 2 "MODULE" H 9150 5000 50 0001 C CNN
F 3 "DOCUMENTATION" H 9150 5000 50 0001 C CNN
-F 4 "620-1019-1-ND" H 9150 5000 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 9150 5000 60 0001 C CNN "Digi-Key"
1 9150 5000
1 0 0 -1
$EndComp
@@ -934,7 +934,7 @@ F 0 "S14" H 9150 5750 50 0000 C CNN
F 1 "A13xx" H 9150 5950 50 0000 C CNN
F 2 "MODULE" H 9150 5850 50 0001 C CNN
F 3 "DOCUMENTATION" H 9150 5850 50 0001 C CNN
-F 4 "620-1019-1-ND" H 9150 5850 60 0001 C CNN "Digi-Key"
+F 4 "620-1548-2-ND" H 9150 5850 60 0001 C CNN "Digi-Key"
1 9150 5850
1 0 0 -1
$EndComp